Compared with ISO20653 and IEC60529, the main difference is in the code K, the code "K" is to describe special requirements for road vehicles. For automotive electrical equipment, the test can be carried out as per ISO20653. The water ingress protection test method specified in ISO20653 refers to the relevant regulations in IEC60529, but except test grades IPX0 to IPX8 according to IEC60529, the ISO20653 increased IPX4K, IPX6K and IPX9K test methods special for automotive electrical equipment.
IEC60529 and IS020653 Comparison Table | |||||||||
IEC60529 | ISO20653 | Test Tools | |||||||
Element | IP | Meaning for protection of electrical equipment | Meaning for the protection of person | Element | IP | Meaning for protection of electrical equipment | Meaning for the protection of person | ||
First code element | 0 | -not protected | not protected | First code element | 0 | -not protected | -not protected | N/A | N/A |
1 | Protected against foreign objects with diameter≥50mm | Protected against access to hazardous parts with back of hand | 1 | Protected against foreign objects with diameter≥50mm | Protected against access to hazardous parts with back of hand | Test Probe A (Access probe) Φ50 rigid sphere with handle Test Force: 50N±10% |
Test Probe 1 (Object probe) Φ50mm rigid sphere without handle Test force: 50N±10% |
||
2 | Protected against foreign objects with diameter≥12.5mm | Protected against access to hazardous parts with finger | 2 | Protected against foreign objects with diameter≥12.5mm | Protected against access to hazardous parts with finger | Test Probe B (Acess probe) Jointed test finger Test force: 10N±10% |
Test probe 2 (Object probe) Φ12.5mm rigid sphere without handle Test force: 30N±10% |
||
3 | Protected against foreign objects with diameter≥2.5mm | Protected against access to hazardous parts with tool | 3 | Protected against foreign objects with diameter≥2.5mm | Protected against access to hazardous parts with tool | Test probe C (Access probe) Rod: Φ2.5-length 100, rigid steel rod Test force: 3N±10% |
Test probe C Rod: Φ2.5-length 100, rigid steel rod Test force: 3N±10% |
||
4 | Protected against foreign objects with diameter≥1.0mm | Protected against access to hazardous parts with wire | 4 | Protected against foreign objects with diameter≥1.0mm | Protected against access to hazardous parts with wire | Test probe D (Access probe) Wire: Φ1.0-length 100, rigid steel wire Test force: 1N±10% |
Test probe D Wire: Φ1.0-length 100, rigid steel wire Test force: 1N±10% |
||
5 | -dust protected | Protected against access to hazardous parts with wire | 5K | Protected against foreign objects with diameter≥1.0mm | Protected against access to hazardous parts with wire | Test probe D (Access probe) Wire: Φ1.0-length 100, rigid steel wire Test force: 1N±10% |
Dust chamber, with or without underpressure (use talcum power as per IEC60529, use Arizona dust as per ISO20653) |
||
6 | -dust tight | Protected against access to hazardous parts with wire | 6K | Protected against foreign objects with diameter≥1.0mm | Protected against access to hazardous parts with wire | Test probe D (Access probe) Wire: Φ1.0-length 100, rigid steel wire Test force: 1N±10% |
Dust chamber, with underpressure (use talcum power as per IEC60529, use Arizona dust as per ISO20653) |
||
Second code element | 0 | Non-Protected | N/A | Second code element | 0 | Non-Protected | N/A | N/A | N/A |
1 | Protected against vertically falling water drops | 1 | Protected against vertically falling water drops | Drip Box Test Apparatus | |||||
2 | Protected against vertically falling watere drops when enclosure tilted up to 15° | 2 | Protected against vertically falling watere drops when enclosure tilted up to 15° | ||||||
3 | Protected against spraying water | 3 | Protected against spraying water | Oscillating tube or swivel tube Testing Equipment Spray nozzle |
|||||
4 | Protected against splashing water | 4 | Protected against splashing water | ||||||
4K | Protected against splash water with increased pressure | ||||||||
5 | Protected against water jets | 5 | Protected against water jets | Jet nozzles Testing Equipment | |||||
6 | Protected against powerful water jets | 6 | Protected against powerful water jets | ||||||
6K | Protected against strong high-velocity water with increased pressure | ||||||||
7 | Protected against the effects of temoprary immension in water | 7 | Protected against the effects of temoprary immension in water | Immesion Tank | |||||
8 | Protected against the effects of continuous immersion in water | 8 | Protected against the effects of continuous immersion in water | High pressure immesion tank | |||||
9 | Protected against high pressure and tempereature water jets | 9K | Protected against high-pressure/steam-jet cleaning | Fan Jet Nozzles Test Chamber | |||||
Note: The code "K" is to describe special requirements for road vehicles |