Product Details:
Payment & Shipping Terms:
|
According To: | IEC60068-2-75, IEC60598, IEC62262 | Weight Of Body: | 1.25kg |
---|---|---|---|
Material: | Stainless Steel + Polyamide | Impact Energy: | 0.14J, 0.20J, 0.35J, 0.50J, 0.70J, 1.0J, 2.0J |
H.S. Code: | 9024800000 | Guarantee: | 12 Months |
Highlight: | impact testing machine,pendulum impact tester |
Adjustable and Single Spring Operated Impact Hammer meet the requirements of IEC60068-2-75 Standard
1. Introduction:
The Spring Operated Impact Hammer was designed and manufactured according to the requirements of IEC 60068-2-75.
The Spring Operated Impact Hammer simulates mechanical impact to electronic products and electrical appliances. The impact hammer is set at the factory to one specific energy level. The energy range available is between 0.14 Nm to 2 Nm (Joule). A compressed spring accelerates a striking element to hit the sample undergoing test. The spring is released from a locking mechanism by pressing the cone-shaped end of the impact hammer against the product under test.
There are several models, although they are of similar construction characteristics, have a different impact energy according to the test requirement. Our Impact Hammers includes single impact energy and six adjustable impact energies.
2. Parameters
Impact energy | 2J | 0.14, 0.2, 0.35, 0.5, 0.7, 1J |
Error | ±0.08J | ±0.08J |
Equivalent mass | 500g±5g | 250g±5g |
Radius of hammer | R25mm | R10mm |
Weight of body | 1250g | 1250g |
Trigger force | <20N | <10N |
Material of hammer | steel | Polyamide |
Material of shell | Stainless steel | Stainless steel |
Degrees of protection against external mechanical impacts
IK01 | IK02 | IK03 | IK04 | IK05 | IK06 | IK07 | IK08 | IK09 | IK10 |
0.14J | 0.2J | 0.35J | 0.5J | 0.7J | 1J | 2J | 5J | 10J | 20J |
Model | Impact Energy |
IK01 (single) | 0.14±0.01J |
IK02 (single) | 0.20±0.02J |
IK03 (single) | 0.35±0.03J |
IK04 (single) | 0.50±0.04J |
IK05 (single) | 0.70±0.05J |
IK06 (single) | 1.00±0.05J |
Ik07 (single) | 2.00±0.10J |
IK08 (single) | 5.00±0.25J |
IK01-IK06 (universal) | 0.14J~1.00J |
3. Picture:
4. Caution
● When not is use, the hammer should be in release conditions.
● When change or adjust the spring, the hammer should be calibrated by the calibration department before using.
● The hammer is a precision instrument, please handle with care and beware of fall.
● Storage condition: Temperature: 5~35℃,box with desiccant.
Contact Person: Ms. Penny Peng
Tel: +86-18979554054