Product Details:
Payment & Shipping Terms:
|
Standard: | JIS8303 | Material: | Stainless Steel |
---|---|---|---|
Application: | For Plug And Socket-outlet | Shipment: | By Express |
Highlight: | electrical plug tester,torque testing equipment |
JISC8303 Plug Socket Tester Japanese Stainless Steel Plug Socket Gauge
No. | Figure number | Gauge description |
1 | JIS C8303 Figure A.1 JIS C8282-1:2010 CL22.1 |
Maximum retaining force gauge (15A125V two-pole) |
2 | JIS C8303 Figure A.1 JIS C8282-1:2010 CL22.2 |
Minimum retaining force gauge (15A125Vtwo-pole) |
3 | JIS C8303 Figure A.1 JIS C8282-1:2010 CL19 |
Test plug for temperature rise test (15A125V two-pole) |
4 | JIS C8303 Figure A.1 JIS C8282-1:2010 CL20/21 |
Breaking capacity, normal operation gauge |
5 | JIS C8303 Figure A.2 JIS C8282-1:2010 CL22.1 |
Maximum retaining force gauge (15A125V two-pole) |
6 | JIS C8303 Figure A.2 JIS C8282-1:2010 CL22.2 |
Minimum retaining force gauge (15A125V two-pole) |
7 | JIS C8303 Figure A.2 JIS C8282-1:2010 CL19 |
Test plug for temperature rise test (15A125V two-pole) |
8 | JIS C8303 Figure A.2 JIS C8282-1:2010 CL20/21 |
Breaking capacity, normal operation gauge |
9 | JIS C8303 Figure A.3 JIS C8282-1:2010 CL22.1 |
Maximum retaining force gauge (20A 125V two-pole) |
10 | JIS C8303 Figure A.3 JIS C8282-1:2010 CL22.2 |
Minimum retaining force gauge (20A 125V two-pole) |
11 | JIS C8303 Figure A.3 JIS C8282-1:2010 CL19 |
Test plug for temperature rise test (20A 125V two-pole) |
12 | JIS C8303 Figure A.3 JIS C8282-1:2010 CL20/21 |
Breaking capacity, normal operation gauge |
13 | JIS C8303 Figure A.4 JIS C8282-1:2010 CL22.1 |
Maximum retaining force gauge (20A 250V two-pole) |
14 | JIS C8303 Figure A.4 JIS C8282-1:2010 CL22.2 |
Minimum retaining force gauge (20A 250V two-pole) |
15 | JIS C8303 Figure A.4 JIS C8282-1:2010 CL19 |
Test plug for temperature rise test (20A 250V two-pole) |
16 | JIS C8303 Figure A.4 JIS C8282-1:2010 CL20/21 |
Breaking capacity, normal operation gauge |
17 | JIS C8303 Figure A.5 JIS C8282-1:2010 CL22.1 |
Maximum retaining force gauge (30A 250V two-pole) |
18 | JIS C8303 Figure A.5 JIS C8282-1:2010 CL22.2 |
Minimum retaining force gauge (30A 250V two-pole) |
19 | JIS C8303 Figure A.5 JIS C8282-1:2010 CL19 |
Test plug for temperature rise test (30A 250V two-pole) |
20 | JIS C8303 Figure A.5 JIS C8282-1:2010 CL20/21 |
Breaking capacity, normal operation gauge |
21 | JIS C8303 Figure A.9 JIS C8282-1:2010 CL22.1 |
Maximum retaining force gauge (15A 125V two-pole+ earthing-pin) |
22 | JIS C8303 Figure A.9 JIS C8282-1:2010 CL22.2 |
Minimum retaining force gauge (15A 125V two-pole + earthing-pin) |
23 | JIS C8303 Figure A.9 JIS C8282-1:2010 CL19 |
Test plug for temperature rise test (15A 125V two-pole+ earthing-pin) |
24 | JIS C8303 Figure A.9 JIS C8282-1:2010 CL20/21 |
Breaking capacity, normal operation gauge |
25 | JIS C8303 Figure A.10 JIS C8282-1:2010 CL22.1 |
Maximum retaining force gauge (15A 250V two-pole + earthing-pin) |
26 | JIS C8303 Figure A.10 JIS C8282-1:2010 CL22.2 |
Minimum retaining force gauge (15A 250V two-pole +earthing-pin) |
27 | JIS C8303 Figure A.10 JIS C8282-1:2010 CL19 |
Test plug for temperature rise test (15A 250V two-pole + earthing-pin) |
28 | JIS C8303 Figure A.10 JIS C8282-1:2010 CL20/21 |
Breaking capacity, normal operation gauge |
29 | JIS C8303 Figure A.11 JIS C8282-1:2010 CL22.1 |
Maximum retaining force gauge (15A 125V two-pole + earthing-pin) |
30 | JIS C8303 Figure A.11 JIS C8282-1:2010 CL22.2 |
Minimum retaining force gauge (15A 125V two-pole + earthing-pin) |
31 | JIS C8303 Figure A.11 JIS C8282-1:2010 CL19 |
Test plug for temperature rise test (15A 125V two-pole + earthing-pin) |
32 | JIS C8303 Figure A.11 JIS C8282-1:2010 CL20/21 |
Breaking capacity, normal operation gauge |
Contact Person: Ms. Penny Peng
Tel: +86-18979554054
Fax: 86--4008266163-29929