Send Message
Home ProductsEMC Test Equipment

1.2/50μs Surge Generator EMC Test Equipment 10KV Open Circuit Output Voltage 20A CDN

China Pego Electronics (Yi Chun) Company Limited certification
China Pego Electronics (Yi Chun) Company Limited certification
Je viens de recevoir les doigts d essais, Je suis très satisfait , c est très bien

—— ESTI Formation

Dear Alice, The machines are working well now. Thank you for your support and patience to solve our problems and give us very useful suggestions in negotiation. Really a good cooperation.

—— TUV Rheinland Pvt. Ltd

Dear Penny, We really appreciate to buying from Pego Group for several years, all products come with good quality amd easy operation.

—— LIA Laboratories Limited

I have received the spring hammers, they are great!

—— BSH Group

Yes we got the probes and our engineers like them. Thanks.

—— Gamma Illumination Pty Ltd

the spring hammer looks good and works fine

—— Sigma Connectivity

This is to confirm the order has been well received and all is in good order. May I thank you for your very professional service.This has been a pleasant transaction.

—— Gallagher Group

절연강도 시험기 잘 받았습니다. 빠른 배송에 감사드리며 차후 또 다른 제품구입시 연락드리겠습니다.

—— 유진코퍼레이션에 황동익입니다.

I am sending this email to let you know that we receive the 2 vessels with the calibration certificate. I would like to thank you for the quality of the vessels and for your good work. I can’t wait to work with you on other topics.

—— Brandt France

we can confirm that it works very well! thank you for the good quality equipment.

—— PPC (Greece)

I'm Online Chat Now

1.2/50μs Surge Generator EMC Test Equipment 10KV Open Circuit Output Voltage 20A CDN

1.2/50μs Surge Generator EMC Test Equipment 10KV Open Circuit Output Voltage 20A CDN
1.2/50μs Surge Generator EMC Test Equipment 10KV Open Circuit Output Voltage 20A CDN 1.2/50μs Surge Generator EMC Test Equipment 10KV Open Circuit Output Voltage 20A CDN

Large Image :  1.2/50μs Surge Generator EMC Test Equipment 10KV Open Circuit Output Voltage 20A CDN

Product Details:
Place of Origin: China
Brand Name: PEGO
Certification: Third-lab Calibration Certificate
Model Number: LSG-1020
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: USD5500-USD12000/set
Packaging Details: carton
Delivery Time: 15 working days
Payment Terms: T/T, Western Union, MoneyGram
Detailed Product Description
Standard: IEC/EN61000-4-5, IEC/EN61850-3, ITU-T K.12, ITU-T K.20, UL1449 Output Voltage: 10KV, 12KV, 15KV (optional)
CDN: 380V/20A (3- Phase) Output Independce: 2ohm, 12ohm 500ohm
Product Name: Combination Wave Generator Warranty: 12 Months
Working Power: AC220±10%,50/60Hz Dimension: 600mm (L)*500mm(W)*1500mm(H)
High Light:

emc testing services

,

electrostatic discharge generator

1.2/50 μs Surge Generator EMC Test equipment with 10KV Open Circuit Output Voltage and 20A CDN​

 

1. Introduction

LSG-1020 Lighting Surge System is confirmed to IEC61000-4-5 and GB/T17626.5. It is the equipment used for Anti-Surge performance test for electronic and electrical products in the industry process measurement and control device. It includes Coupling/ Decoupling Network (CDN), which can be used for the Surge immunity test in the power line.

 

There are two main reasons causing lightning shock:

Switching Transients:

Switching transients is related with the following factors:

1). The switch disturbance of the main power supply, such as the switching of capacitor bank.

2). The start or stop of other devices near the tested equipment, as well as the changes of the load in the power distribution system.

3). Switching the SCR device with resonance circuit.

4). All kinds of system failures, such as short circuit and arc fault of equipment grounding network or grounding system.

 

The Lightning Transient

The generating mechanism of lightning transient:

1). The lighting hits directly external (outdoor) line and injects large amount of current, which flows through the ground resistance or surge impedance generates voltage in external line.

2). Indirect lightning (clouds within or lightning between clouds) may induce voltage in the circuit line in or out the building.

3). It will form an electromagnetic field when a lightning shock did not hit the line but the objects near the line and the electromagnetic field can cause the induced voltage of the external circuit line.

4). The generated interference is produced when lightning current nearby equipment discharges directly and the lightning ground current flows and couples in the public grounding system of equipment.

5). In addition, the rapid changing of current and voltage may also be coupled into the interior of the equipment when some protectors of the equipment are incentive.

 

2. Introduction of Surge Generator:

 

LSG-6K10 surge generator is designed according to IEC61000-4-5 and GB/T17626.5,and completely meet the requirements of the standards. It is widely used in the fields of industry control equipment, house-holding appliance,medical electronics, communications electronics,components, auto control equipment and etc.

 

Lightning surge generator is to simulate the surge voltage caused by switching transient and lightning transient, the surge test is to found out the surge voltage effect to EUT in normal working condition.

 

The lightning surge generator can generates both 1.2/50, 8/20 µs combination wave. The open circuit output voltage is from 0.2KV~10KV, and short-circuit output current is up to 5KA, ser can choose and define the test levels. The parameters of waveform for surge voltage and waveform for surge current is strictly meet the standard requirements of IEC61000-4-5.

 

The Lightning surge generator is built in a 3 phase 380V/20A coupling and decoulping network, the coupling mode includes L1-N,L2-N,L3-N, L1-PE,L2-PE,L3-PE,N-PE. 

 

 

3. Features of Surge Generator:

 

1). 7 inches LCD touch screen, with plentiful functions, easy to operation and update the software.

User can design the test program, and has 1000 groups memories.

2). Monitoring the surge voltage and current waveform by work with an external oscilloscope.

3). Built in single phrase 10A (16A) network, makes the equipment smaller and convenient.

4). With high-strength plug in the panel, EUT can connect with the equipment convenient and reliable.

5). Monitoring the work voltage and current of the EUT. Overvoltage protection and overcurrent protection.

6). Intelligent test the surge output, warning at voltage error and no output.

7). Intelligent judge the abnormal of high voltage and surge output.
 
4. Parameters of Surge Generator:

Output voltage (open)0.2-10kV ±5%
Front time1.2μs ±30%
Time to half-value50μs ±20%
Output current (short)5kA±5% (max)
Front time8μs ±20%
Time to half-value20μs ±20%
Output polarityPositive, negative, positive/negative automatically
Output impedance2Ω±10%, 500Ω±10%
Trigger modeSynchronization, asynchronization
Inject phaseFreely set at 0-360°,resolution:1°
Trigger modeAuto or manual, single
Surge times1-9999 times
Memories1000 groups, built in IEC standard
Surge interval30-9999s
Built-in surge voltage monitoring attenuation ratio1000:1
Built-in surge current monitoring attenuation ratio1000:1
Built in network capacity3 phase, 380V/20A
Coupling modeL1-N,L2-N,L3-N, L1-PE,L2-PE,L3-PE,N-PE
Coupling device18μF capacitance (line to line), 10Ω resistor+9μF capacitance (line to ground)
Working environmentTemperature:15°C-35°C humidity:10%-75%
Power supplyAC220±10%,50/60Hz
Weight270kg
Dimension600mm (L)*500mm(W)*1500mm(H)
 
 
5. Picture
 1.2/50μs Surge Generator EMC Test Equipment 10KV Open Circuit Output Voltage 20A CDN 0

  
 