Product Details:
Payment & Shipping Terms:
|
Reference Standard: | IEC60695-11-5 (IEC60695-2-2), EN60695, GB/T51669.5, GB4706.1 | Shell Material: | Coating Metal Sheet |
---|---|---|---|
Name: | Fire Hazard Testing Equipment | Controller: | Single Chip And Push Button |
Dimension: | 1000mm(W)*650mm(D)*1300mm (H) | Working Power: | Single Phase 220V/50-60Hz |
Warranty: | 12 Months | Shipment: | By Sea Or Air |
Highlight: | electrical testing instruments,electric test meter |
IEC60695 45 Degree Tilted Needle Flame Test Apparatus Fire Hazard Protection Testing Equipment
1. Introduction
The Needle Flame Tester consists of a dia.0.9mm needle burner that tilts to 45 degree from the vertical and is fueled with butane gas. The fire hazard of the specimen is assessed by measuring the burning duration of the specimen, and any ignition of the wrapping tissue and white pine board below the specimen. Needle flame tester is designed according to IEC60695-11-5(IEC60695-2-2). It is applicable to ignition hazard test, combustibility test of electronic industry and home electronic appliance. The equipment specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess product and material’s ignition risk and fire resistance by a simulation technique the fire.
The needle flame test apparatus is controlled by single chips and push buttons, the shell is made of coating metal sheet. The test apparatus is built-in air exhaust. The front panel is transparent for easy observation of the experimental process. Avoid gas leakage explosion caused by circuit leakage or short circuit, the equipment has self-contained gas flow size alarm device.
2. Parameter
Burner |
Inner diameter: Φ 0.5mm ± 0.1mm Outer diameter: ≤Φ 0.9mm Length: 35mm, Material: stainless steel |
Burner angle | 450 or 900 |
Ignition layer | White pine board with thickness 10mm, and cover with wrapping tissue 12g/m2 ~30g/m2 |
Application time | 0-999.9s±0.1s adjustable (normally 30s) |
Burning duration | 0-999.9s±0.1s (auto record, manual pause) |
Flame height | 12mm ± 1mm (adjustable), Measuring with a steel ruler |
Burn gas | ≧95% butane gas or propane gas |
Flame requirement | rising time from 100℃±2℃ to 700℃±3℃ should within 23.5s±1s |
Thermocouple | Φ0.5mm K type thermocouple (The insulating sleeve heat resist to 1100 ℃) |
Temperature sensor | Copper with Φ4mm and 0.58±0.1g weight, equip with K type thermocouple |
Thermal radiation baffle | Automatic masking |
Safe operation interface | automatically power off upon open the glass window |
Test space | ≥ 0.5m3 , matte black background, illuminance ≤ 20Lux, exhaust hole: Φ70mm (Power on automatic work) |
Test period | auto control |
Pick-up tray | Yes |
Gas calibration device | Built-in temperature measuring box, gas calibration can be executed before test |
Standard | IEC60695-11-5 (IEC60695-2-2), EN60695, GB/T51669.5, GB4706.1 |
Equipment size | 1000mm(W)*650mm(D)*1300mm (H) |
Power supply | AC220±10%, 50Hz, 0.3KVA |
3. Working studio
4. FAQ
1). What is the warranty period of the equipment?
Answer: the equipment warranty is 12 months upon you receipt of the equipment
2). Can you provide third-lab calibration certificate?
Answer: Yes, the equipment can send to the third-labs authorized by ISO17025 and get the calibration certificate, but the buyer should undertake the charges.
3). What is the working power of the equipment?
Answer: single phase 220v/50-60Hz
4). What is the language of the operation interface?
Answer: English
Contact Person: Ms. Penny Peng
Tel: +86-18979554054
Fax: 86--4008266163-29929