Normative Standard: | IEC61347-1 Figure D.1 And Annex D | Working Dimension: | L610mm * W610mm * H610mm |
---|---|---|---|
Dimension Of Test Compartment (floor): | L560mm * W560mm * D25mm | Test Object: | Thermally Protected Lamp Controlgrear (ballasts) |
1. Introduction
The heating enclosure is designed according to IEC61347-1 figure D.1 and annex D, for carrying out the heating test of thermally protected lamp controlgrear.
2. Specification
Inner dimension |
L610mm * W610mm * H610mm |
Overall dimension |
L660mm * W660mm * H760mm |
Dimension of test compartment (floor) |
L560mm * W560mm * D25mm |
Height of heater compartment |
75mm |
Structure of front door |
Up-and-down sliding type, with an opening size of 150×150 mm, and sealed by an aluminium semicircular structural component. |
Sample supports |
Designed according to figure D.1 of IEC61347-1 |
Heating elements |
Heating element: 300W strip stainless steel heater. Heat sink: brass heat sink. Heat sink dimensions: L40×W40×L300 mm. Quantity: 1 set. Heating control: temperature sensing by thermocouple, controlled by temperature controller. |
Control unit |
The temperature controller is installed on the front of the electrical box. Temperature control adopts PID control mode. Heating elements are controlled by solid-state relays. |
Test temperature |
40℃ |
Working power |
220V±10%, 50Hz |