Glow wire testing is an electrical safety test designed to evaluate the flame resistant properties of plastic materials used in electrical devices. IEC60695-2-11 describes the glow-wire test conducted on end products (the GWEPT, or glow-wire end product test). Its purpose is to ensure the end ... Read More
|
![]() |
Withstand voltage tester can be called electrical insulation strength tester, dielectric strength tester, high voltage tester, hipot tester and etc. Its woking pricinple is: a specified AC or DC high voltage is applied between the live part of the appliance and the non-charged part (generally the ... Read More
|
![]() |
For heating appliance and combined appliance: 1. Appliances normally placed on a floor or table in use, are placed on the floor and as near to the wall as possible. 2. Appliances normally fixed on a wall shall fixed on one of the walls, and as near to other wall and floor or ceiling as is likely to ... Read More
|
![]() |
ISO17025 is the international standard for laboratory accreditation services; the latest version is released in May, 2005. The full name of ISO/IEC17025:2005-5-15 is Accreditation Criteria for the Competence of Testing and Calibration Laboratories. ISO17025 standard is the laboratory management ... Read More
|
![]() |
According to their designation, the test probes can be classified as: IP code probes Other probes According to the kind of protection they are intended to check: Access probes Object probes According to the specific hazard they are intended to check: Probes mainly intended to be used to verify the ... Read More
|
![]() |
Question 1: What should we do if the nozzles do not spray water? Answer: 1). Firstly, user should check the water filter if it should be changed. 2).Secondly, the air compressor can be used to air dry the nozzles to check if they are clogged. 3). Replace with spare nozzles and try again. Question 2: ... Read More
|
![]() |
Negative pressure leak test machine is strange to everyone. In fact, it is a equipment that performs IPX8 waterproof inspection on the outer casing of the product through the principle of negative pressure detection. It is differ from the traditional water immersion tank, the leak points can be ... Read More
|
![]() |
UL94 is the most widely used flame retardant performance evaluation standard for plastic materials, with a total of 12 classifications: HB, V-0, V-1, V-2, 5VA, 5VB, VTM-0, VTM-1, VTM-2, HBF , HF-1, HF-2. UL94 covers tests for flammability of polymeric materials used for parts in devices and ... Read More
|
![]() |
Our old client is a very large local distributor in Malaysia and has more than 10 offices across the ASEAN region. They purchased 1 set test probe for Sumsung from Pego last year, both of them are very pleased with our products’ quality and services, therefore we establish a good relationship with ... Read More
|
![]() |
The draught-proof enclosure is rectangular, with a double skin on top and on at leat three sides and with a solid base, the double skins are of perforated metal, space approximately 150mm apart, with regular perforations of 1mm to 2mm diameter, occupying about 40% of whole area of each skin. It is ... Read More
|